Version History
Here you can find the changelog of VEGA Tools since it was posted on our website on 2019-07-13.
The latest version is and it was updated on soft112.com on 22 April, 2024.
See below the changes in each version:
version N/A
posted on 2024-03-25
Service communication improved
version N/A
posted on 2024-03-04
This release contains various improvements and bug fixes.
version N/A
posted on 2023-11-08
Error when loading the echo curve fixed
version N/A
posted on 2023-11-02
Novelties:
• Quick and easy creation/saving of device documentation, both locally or centrally in myVEGA
• Group function for backup & restore data
• New assistant for creation of the linearization function for complex tank geometries
• VEGABAR series 20/30: additional languages and scaled measured values on the display
• VEGAPULS 42: adjustment possibilities for indication on the display
• VEGAPOINT series 20/30: Optimizations in the adjustment function
• VEGAPULS 6X: Setup assistant optimised
version N/A
posted on 2023-08-07
Update contains bugfix for flow calculation when using the linearisation wizard
version N/A
posted on 2022-12-06
Fixed login error
version N/A
posted on 2022-03-21
Bug fixes
version N/A
posted on 2022-01-12
Novelties setup:
. New menu item: Test & Documentation
. Documentation: Device test added for VEGABAR series 80, VEGADIF series 80, VEGAFLEX series 80, VEGAPULS series 10/20/30/ C10/C20, VEGAPULS series 60
. Documentation: SIL proof test added for VEGAFLEX series 80
. Documentation: WHG proof test added for VEGAPOINT series 20
version N/A
posted on 2021-10-26
Novelties Setup:
- Using a new search field for setup, it is now possible to quickly and directly switch to the desired parameters
- VEGABAR/VEGAFLEX series 80: Assistant for device test added
- PLICSMOBILE T81: Modification of network access code (PSK) possible
version N/A
posted on 2021-07-26
Novelties:
. After a Bluetooth connection to the sensor/device has been established, the communication now remains permanent. This means that the Bluetooth connection is no longer interrupted when, for example, messages or phone calls put the VEGA Tools app in the background.
version N/A
posted on 2021-05-04
Fault rectification:
. Documentation: An error in the proof test acc. to WHG/SIL was fixed.
version N/A
posted on 2021-04-30
Novelties:
. Documentation: For VEGASWING 61/63/66 assistant for proof test acc. to WHG/SIL added (it is necessary to enter the serial number)
. Setup: "Device details" added for all sensors/devices
. Setup: VEGAMET 140/340/800 series: Application assistant gauge measurement added
. Setup: VEGAMET 142/342/842/862: The applications can be reset individually
Fault rectification:
. Sensor Orientation help: An error in the calculation of the angle was fixed
version N/A
posted on 2021-02-23
Problems with the barcode scanner have been fixed.
version N/A
posted on 2021-02-22
Novelties:
. Support new products: VEGAPULS Air 41, 42 and VEGAPOINT 24
. VEGAMET 140/340/800 series: Additional application assistants added
. Improvements/Integration coloured status indication: VEGABAR 20/30 series, VEGAPOINT 20/30 series, VEGAMET 140/340/800 series
version N/A
posted on 2021-01-19
Fixed document download issue
version N/A
posted on 2020-12-15
Novelties:
. VEGABAR 20/30 series: 360° status indication for three-wire added
. VEGABAR/VEGAPOINT 20/30 series: Status indication 5th operating condition added
. VEGAMET 842/862: Application assistant rain overflow basin added
. VEGAPULS series: Manual false signal suppression added
Fault rectification:
. Xiaomi smartphones: The automatic establishment of a Bluetooth connection by Android prevented sensors from being selected in the device search.
version N/A
posted on 2020-10-20
Novelties:
. Bluetooth device list: Filtering with plain text input added
. Bluetooth device list: Display of the last used device/sensor as first list entry
. VEGAPULS (C) 10, (C) 20, 30 series / VEGAMET 800 series: Linearization using Q/h table added
. Support new products: VEGAMET 140 series, VEGAMET 340 series
version N/A
posted on 2020-09-22
BugFix:
The alignment aid with the camera now works correctly again.
version N/A
posted on 2020-08-21
Novelties:
. Function extensions for future PROTRAC software version added.
. VEGABAR series 20/30: Adjustment for „Operating states“ added for the illuminated ring.
version N/A
posted on 2020-08-11
Novelties:
. Function extensions for future VEGAPULS software version added.
Fault rectification:
. Flow measurement (ISO standards): Error in conversion from metric to imperial units corrected.
. VEGAMET series 800: Error in the adjustment "Mode of pump control" corrected.
version N/A
posted on 2020-07-08
Fault rectification:
. VEGAMET series 800: Error in the pump control, in connection with the relay, fixed.
. Error in displaying documentation by using serial number fixed.
version N/A
posted on 2020-06-19
Fault rectification:
. Small improvements in performance.
version N/A
posted on 2020-03-17
Novelties:
. Setup VEGAFLEX 80 series, VEGAPULS 64/69: linearization assistant (gauging by litres) added
. Message for missing location determination for using Bluetooth added
Fault rectification:
. VEGAPOINT 20/30 series: Error when entering the adjustment values with medium removed
. VEGAMET 800 series: Fault indication of the unit for pulse output with flow measurements (relay as pulse generator)
. Display of searched serial numbers: Redundant display was removed
version 5.6.906
posted on 2020-01-22
Fault rectification:
. Diagnosis: Error in the display of the event list eliminated on the tablet.
. Diagnosis: Error in the display of the device features for the new sensors / devices eliminated.
. Setup: Error in updating the menu items when changing the colours on VEGABAR series 20/30 and VEGAPOINT series 20 elminated on the tablet.
version 5.6.878
posted on 2019-12-19
Novelties:
. Support new products: VEGABAR 20/30 series, VEGAMET 800 series, VEGAPULS 10/20/30 series, VEGAPOINT 20 series
version 5.5.816
posted on 2019-09-06
. Stability and performance improved
version 5.4.758
posted on 2019-07-09
Fault rectification:
. PLICSCOM with Bluetooth: Fixed communication problems with software version 1.11.1
. Bluetooth access code: Fixed issues with leading zeros